Configure the Home Gateway for communication with the Thinknx server.
Home Gateway LED indicators:
Purple = Thinknx mode active
Blue = Gewiss mode active (compatible with the Gewiss app)
Option 1 – Standard Home Gateway Configuration
Perform the commissioning following the standard procedures
Proceed with integration using the software Thinknx Up Configurator - Cloud
Option 2 – Configuration via Thinknx Up
Open the Thinknx Up app
Go to the Settings menu
Scroll to the bottom and select Start Gewiss System Configuration
Press and hold the Home Gateway programming button for 4 seconds until the LED starts blinking
Wait for the blinking to stop to complete the association
Enter the Wi-Fi network name (SSID), respecting uppercase and lowercase
Enter the Wi-Fi password
Select the security type (e.g., WPA2-PSK2)
Enable Thinknx if available
Enter the Thinknx server IP address
Programming via Thinknx Up Configurator
An active server is required to program via Thinknx Up Configurator.
Launch Thinknx Up Configurator
Configure the server as usual with:
Connection type (serial)
IP address
Password
Etc…
Go to the System section
Click Add and select Gewiss Home Gateway
(One per system; multiple hubs can be managed inside it)
Select Hubs and click to open the collection
Click Add Hub
Then click on the three dots next to Plants to open the configuration
Connection Status Window
Bottom right – Hub connection status:
Green LED – Connection active and working
Yellow LED – Problem detected (hover over the message for details)
Red LED – No connection to the hub
Bottom left – Status of the last loaded configuration (present/not present)
Configuration Modes
Cloud
Downloads the configuration previously saved in the Gateway cloud
Local
Displays the hubs detected by MAC Address
The following options are available:
Create New Configuration
Delete Configuration
Retrieve Configuration from Hub
Configuration Tabs
Viewer
Displays the list of devices in the system (empty for a new configuration)
Parameter
Edit parameters for each device
Right-click a device to rename it.
Sensor
Configure the motion sensors
Network
Add devices:
Open Permit Join – starts the search for devices on the system
Add Device – adds the found devices to the project
Bindings
Associate commands to inputs or actuators
Smart Plate
Two configuration modes:
Localize – press the programming button on the plate to identify it
List – select the plate from the MAC Address list
Notes:
Devices are programmed from left to right
A button to add traditional devices is available at the bottom right
It is possible to configure shift through the Smart Plate management
Associations for Thinknx Up and KNX
Go to System
Select Gewiss Home Gateway
Select the desired Hub
The following sections allow KNX address assignments:
Light
Assign KNX addresses for each Home Gateway light
Thermostat
Assign KNX addresses for each Home Gateway thermostat
Shutter
Assign KNX addresses for each Home Gateway motorized device
Analog
Assign KNX addresses for analog values collected from Home Gateway devices
Object Assignment for Control
Within the Shutter/Light/Thermostat/Analog Value objects, it is possible to change the bus type to Gewiss Home Manager, select the hub, and assign the specific device.