lm_logic_lmatrix

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
lm_logic_lmatrix [2017/09/27 10:57] wikiadminlm_logic_lmatrix [2019/03/20 17:04] (current) – external edit 127.0.0.1
Line 4: Line 4:
  
 The Logic Matrix, given some inputs determined by the **Number of inputs** property and some outputs determined by the **Number of outputs** property, forwards the value of a selected input to a selected output. The selection of inputs and outputs is decided by the value of two inputs, **Input selector** and **Output selector**.\\ The Logic Matrix, given some inputs determined by the **Number of inputs** property and some outputs determined by the **Number of outputs** property, forwards the value of a selected input to a selected output. The selection of inputs and outputs is decided by the value of two inputs, **Input selector** and **Output selector**.\\
-The **Data type** property determines the inputs and outputs data type managed by the matrix; if it is set to //1 bit Boolean//, the inputs and outputs are the standard connectors for all the logic nodes as explained here.+The **Data type** property determines the inputs and outputs data type managed by the matrix; if it is set to //1 bit Boolean//, the inputs and outputs are the standard connectors for all the logic nodes as explained [[logic_module#input_connectors|here]], otherwise the **Inverted** property on the connectors won't be available.
  
 == Input and Ouput selectors == == Input and Ouput selectors ==
Line 11: Line 11:
   * **Default control value** It indicates the default input/output with a number [0-255] representing the 0-base index of the input/output.   * **Default control value** It indicates the default input/output with a number [0-255] representing the 0-base index of the input/output.
   * **Update every control value** If enabled in the Input selector, outputs will be updated for every value received by the Input selector. If disabled, outputs will be refreshed only when the selected input receives a new value or, if this property is enabled in the Output selector, when the Output selector receives a new value.   * **Update every control value** If enabled in the Input selector, outputs will be updated for every value received by the Input selector. If disabled, outputs will be refreshed only when the selected input receives a new value or, if this property is enabled in the Output selector, when the Output selector receives a new value.
- 
-== Input connectors == 
- 
- 
- 
-== Output connectors == 
- 
  • lm_logic_lmatrix.1506502634.txt.gz
  • Last modified: 2019/03/20 17:03
  • (external edit)