system_objs [2020/01/14 20:36] – [System] ingrid | system_objs [2020/04/07 13:27] – [Z-Wave Controller] ingrid | ||
---|---|---|---|
Line 84: | Line 84: | ||
* **Server client port** Number of the TCP port needed to remotely connect with the server (outside the server network). The default port is 7550. | * **Server client port** Number of the TCP port needed to remotely connect with the server (outside the server network). The default port is 7550. | ||
* **Local IP address** IP address (for example 192.168.X.X) needed to connect with the server from clients that operate in the server LAN. | * **Local IP address** IP address (for example 192.168.X.X) needed to connect with the server from clients that operate in the server LAN. | ||
- | * **KNXNet/IP interface** if enabled, the Thinknx server can be used as a KNXNet/IP interface, allowing KNX programming from the ETS software for example. | + | * **KNXNet/IP interface** if enabled, the Thinknx server can be used as a KNXNet/IP interface, allowing KNX programming from the ETS software for example. More information are available on the [[knxnet_ip| KNXnet/IP]] guide. |
* **KNXNet/IP different IP** if enabled, permits to choose a different KNXNet/IP interface to connect and access the KNX bus. | * **KNXNet/IP different IP** if enabled, permits to choose a different KNXNet/IP interface to connect and access the KNX bus. | ||
* **Clients Ph. Address Base** base physical address for the clients connections. | * **Clients Ph. Address Base** base physical address for the clients connections. | ||
Line 1170: | Line 1170: | ||
* **Communication Type** Define the method and mean of communication. Serial over TCP is used when a Serial Server is used.\\ If in the property ”Communication Type” is selected the setting ”Modbus Serial”, the following properties will appear: | * **Communication Type** Define the method and mean of communication. Serial over TCP is used when a Serial Server is used.\\ If in the property ”Communication Type” is selected the setting ”Modbus Serial”, the following properties will appear: | ||
- | * Port Number: Serial port number. | + | * Port Number: Serial port number |
+ | * Compact: use 0. | ||
+ | * Rack: for the 2 RS-232 ports use 0 and 1. For the additional green ports use 2 and 3. | ||
+ | * Brickbox: for RS-232 use 4. For RS-485 use 5. | ||
+ | * When using a USB port, use 10. | ||
* Baud Rate: Modbus Baud Rate | * Baud Rate: Modbus Baud Rate | ||
* Data Length: Number of bits for data | * Data Length: Number of bits for data | ||
Line 1322: | Line 1326: | ||
{{ : | {{ : | ||
- | It allows to integrate Z-Wave devices. Without any gateway, the result is a reliable and easy-to-use system with a bidirectional connection between Z-Wave and other standards such as KNX. | + | It allows to integrate Z-Wave devices. Without any gateway, the result is a reliable and easy-to-use system with a bidirectional connection between Z-Wave and other standards such as KNX. |
+ | |||
+ | <WRAP important center round 60%> For a full list of all the compatible Z-wave devices with Thinknx server, visit this link here http:// | ||
* **Use internal controller** If enable, it will be used the server internal Z-Wave controller. If disabled it will be possible to use an external Z-Wave controller. This option is only used during configuration phase. If disabled, following properties will appear: | * **Use internal controller** If enable, it will be used the server internal Z-Wave controller. If disabled it will be possible to use an external Z-Wave controller. This option is only used during configuration phase. If disabled, following properties will appear: |