system_objs

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revisionBoth sides next revision
system_objs [2020/03/02 16:31] – [Gateway Modbus] ingridsystem_objs [2020/04/17 10:53] ingrid
Line 1219: Line 1219:
  
   * **IP Address** IP address of the device or of the serial server   * **IP Address** IP address of the device or of the serial server
-  * **Port Number** Serial port number. It can be between 0 and 3. For USB use 10+  * **Port Number** Serial port number that changes depending on the server used: 
 +      * Compact: use 0. 
 +      * Rack: for the 2 RS-232 ports use and 1. For the additional green ports use 2 and 3
 +      * Brickbox: for RS-232 use 4. For RS-485 use 5. 
 +      * When using a USB port, use 10.
   * **Lights** Collection of lights   * **Lights** Collection of lights
   * **Automation**    * **Automation** 
Line 1326: Line 1330:
 {{ :system_obj_-_zwave.png?nolink&100 |}} {{ :system_obj_-_zwave.png?nolink&100 |}}
  
-It allows to integrate Z-Wave devices. Without any gateway, the result is a reliable and easy-to-use system with a bidirectional connection between Z-Wave and other standards such as KNX.+It allows to integrate Z-Wave devices. Without any gateway, the result is a reliable and easy-to-use system with a bidirectional connection between Z-Wave and other standards such as KNX.  
 + 
 +<WRAP important center round 60%> For a full list of all the compatible Z-wave devices with Thinknx server, visit this link here http://www.thinknx.com/v3/php/products.php. </WRAP>
  
   * **Use internal controller** If enable, it will be used the server internal Z-Wave controller. If disabled it will be possible to use an external Z-Wave controller. This option is only used during configuration phase. If disabled, following properties will appear:   * **Use internal controller** If enable, it will be used the server internal Z-Wave controller. If disabled it will be possible to use an external Z-Wave controller. This option is only used during configuration phase. If disabled, following properties will appear:
Line 1598: Line 1604:
 This object represents the interface between ThinKnx system and a third-party device connected through serial port. It makes possible to send commands through the serial port to the device. This object represents the interface between ThinKnx system and a third-party device connected through serial port. It makes possible to send commands through the serial port to the device.
  
-  * **Port Number** Serial port number. It can be between 0 and 3. For USB use 10.+  * **Port Number** Serial port number that changes depending on the server used: 
 +      * Compact: use 0. 
 +      * Rack: for the 2 RS-232 ports use and 1. For the additional green ports use 2 and 3
 +      * Brickbox: for RS-232 use 4. For RS-485 use 5. 
 +      * When using a USB port, use 10.
   * **Baud Rate** Serial port baud rate.   * **Baud Rate** Serial port baud rate.
   * **Data Length** Number of bits for data.   * **Data Length** Number of bits for data.
Line 1859: Line 1869:
      * IP address: Device IP address.      * IP address: Device IP address.
      * Port number: TCP/IP port number for ethernet connection.\\ If the property ”Use serial port” is set to ”Enabled”, the following property will be displayed:      * Port number: TCP/IP port number for ethernet connection.\\ If the property ”Use serial port” is set to ”Enabled”, the following property will be displayed:
-     * Serial port: Server serial port number.+     * Serial port: Serial port number that changes depending on the server used: 
 +      * Compact: use 0. 
 +      * Rack: for the 2 RS-232 ports use 0 and 1. For the additional green ports use 2 and 3. 
 +      * Brickbox: for RS-232 use 4. For RS-485 use 5. 
 +      * When using a USB port, use 10.
  
 ==== Object commands ==== ==== Object commands ====
Line 1896: Line 1910:
     * IP address: Device IP address.     * IP address: Device IP address.
     * Port number: TCP/IP port number for ethernet connection.\\ If the property ”Use serial port” is set to ”Enabled”, the following property will be displayed:     * Port number: TCP/IP port number for ethernet connection.\\ If the property ”Use serial port” is set to ”Enabled”, the following property will be displayed:
-    * Serial port: Server serial port number.+    * Serial port: Serial port number that changes depending on the server used: 
 +      * Compact: use 0. 
 +      * Rack: for the 2 RS-232 ports use 0 and 1. For the additional green ports use 2 and 3. 
 +      * Brickbox: for RS-232 use 4. For RS-485 use 5. 
 +      * When using a USB port, use 10.
   * **Mute KNX Group** KNX group for mute command.   * **Mute KNX Group** KNX group for mute command.
  
Line 1939: Line 1957:
     * //TV brand LCD//     * //TV brand LCD//
     * //TV brand NEC//     * //TV brand NEC//
-  * **Serial port** Server serial port number.+  * **Serial port** Serial port number that changes depending on the server used: 
 +      * Compact: use 0. 
 +      * Rack: for the 2 RS-232 ports use 0 and 1. For the additional green ports use 2 and 3. 
 +      * Brickbox: for RS-232 use 4. For RS-485 use 5. 
 +      * When using a USB port, use 10.
  
 ==== Object Commands ==== ==== Object Commands ====
Line 1981: Line 2003:
     * IP address: Device IP address.     * IP address: Device IP address.
     * Port number: TCP/IP port number for ethernet connection.\\ If the property ”Use serial port” is set to ”Enabled”, the following property will be displayed:     * Port number: TCP/IP port number for ethernet connection.\\ If the property ”Use serial port” is set to ”Enabled”, the following property will be displayed:
-    * Serial port: Server serial port number. +    * Serial port: Serial port number that changes depending on the server used: 
 +      * Compact: use 0
 +      * Rack: for the 2 RS-232 ports use 0 and 1. For the additional green ports use 2 and 3. 
 +      * Brickbox: for RS-232 use 4. For RS-485 use 5. 
 +      * When using a USB port, use 10.
  
 ==== Object commands ==== ==== Object commands ====
  • system_objs.txt
  • Last modified: 2024/05/27 14:10
  • by francesco