generic_commands [2019/08/29 09:56] – [Generic Commands] ingridgeneric_commands [2019/10/21 19:20] ingrid
Line 1: Line 1:
 ====== Generic Commands ====== ====== Generic Commands ======
  
-\\  When an object is added to the System, a list of all the commands related to this object will be accessible, if applicable. These commands can be used on a generic button, inside the logic module, in a universal gateway, etc.+\\  When an object is added to the System, a list of all the commands related to this object will be accessible, if applicable. These commands can be used on a generic button, inside the logic module, with the universal gateway, etc.
  
 The commands are grouped into 5 categories: The commands are grouped into 5 categories:
Line 68: Line 68:
    * **Push Notification Identifier** A small descriptive text to allow the system to differentiate a push notification from another one when calculating the rate limit. Mandatory only if the previous parameter has been used.     * **Push Notification Identifier** A small descriptive text to allow the system to differentiate a push notification from another one when calculating the rate limit. Mandatory only if the previous parameter has been used. 
 Using the Universal Gateway, a push notification can be sent to the client when a 1-bit value is received from the bus to indicate that the Water Tank Level is low. The message in that case can be "Low Water Level!". If the 1-bit is being sent periodically to the bus with a small interval, then a maximum number of push notifications can be inserted in the related parameter. Using the Universal Gateway, a push notification can be sent to the client when a 1-bit value is received from the bus to indicate that the Water Tank Level is low. The message in that case can be "Low Water Level!". If the 1-bit is being sent periodically to the bus with a small interval, then a maximum number of push notifications can be inserted in the related parameter.
 +<WRAP important round center 60%>Push notifications only work with internet connectivity. In addition, the server and client should both have the same version of Thinknx software (both Classic or Thinknx UP).</WRAP>
 ++++ ++++
 ++++Execute MS Windows Command: GENERAL| This command allows to launch an .exe file directly from the ThinKnx application on all Players for Windows. ++++Execute MS Windows Command: GENERAL| This command allows to launch an .exe file directly from the ThinKnx application on all Players for Windows.
Line 815: Line 816:
 After selecting **IR Transmitter**, a list of all the transmitters created in the System tab will be shown. The available commands when selecting one of the transmitters are the following: After selecting **IR Transmitter**, a list of all the transmitters created in the System tab will be shown. The available commands when selecting one of the transmitters are the following:
  
-++++Send the selected command for the selected remote|  This command will allow to send an IR command by selecting it from the list to the right. It is possible to send multiple commands by pressing "Enqueue" and choosing another one from the list, as well as adding a pause between the commands. +++++Send the selected command for the selected remote|  This command will allow to send an IR command by selecting it from the list to the right. 
-The Output Option will allow the user to send the IR commands to the selected outputs of the IR transmitter.+{{ ::ir_command_definitio.png?direct&600 |}} 
 +If you want to select a defined output different from the default one, before enqueuing the command, it is possible to enable the "Output option" and select the desired output from the list. The enqueued command will appear on the list of the commands to execute with an appended index corresponding to the selected output. 
 +{{ ::ir_command_definition_with_output_option.png?direct&600  |}} 
 +It is possible to create complex macro of IR operations simply enqueuing more commands. Commands can be separated by pause adding the ”Make pause” item in order to grant a better reception. The sequence displayed in the box on the bottom of the page can be edited by deleting single items or moving them by clicking on ”Up” and ”Down” buttons 
 +{{ ::ir_command_definition_with_macro.png?direct&600  |}} 
 ++++ ++++
 +
  