Line 650: Line 650:
 ==== Areas ==== ==== Areas ====
 This parameter holds the collection of all the areas (rooms or part of the building) limited by one or more access control keypads. By clicking on the small button to the right, the Area Manager is accessible. Each added area will have the following parameters: This parameter holds the collection of all the areas (rooms or part of the building) limited by one or more access control keypads. By clicking on the small button to the right, the Area Manager is accessible. Each added area will have the following parameters:
 +  * **Name** label of the area.
 +  * **Entrance doors** allows you to select the checkers that are used on site to enter this specific area. The checkers should be created first in the **Keypads** collection.
 +  * ** Dual flow** id disabled, the entrance checkers will be considered for both entrance and exit. If enabled, it means the area has differet doors/checkers for entrance and exit. It permits to distinguish entrance and exit events and eventually count the people inside the area.
 +  * **Exit doors** //only visible if **Dual flow** is enabled.// allows you to select the checkers that are used on site to exit this specific area. The checkers should be created first in the **Keypads** collection.
 +  * **Count persons** //only visible if **Dual flow** is enabled.// If enabled, the system will count the number of persons inside the area based on the entrance and exit events.
 +  * **Success enter command** Command to execute in case of successful entrance event.
 +  * **Success exit command** Command to execute in case of successful exit event.
 +  * **Nobody command** //only visit if **Count persons** is enabled.// Command to execute in case nobody is in the area.
 +  * **KNX group force closed** KNX group (1 bit DPT1) to force all doors/checkers to refuse any code.
 +  * **KNX group force open** KNX group (1 bit DPT1) to force all doors/checkers to accept any code.
 +  * **KNX group valid enter** KNX gorup (1bit DPT1) to signal a valid entrance into the area.
 +  * **KNX group valide exit** KNX group (1bit DPT1) to signal a valid exit from the area.
  