Line 1170: Line 1170:
  
   * **Communication Type** Define the method and mean of communication. Serial over TCP is used when a Serial Server is used.\\ If in the property ”Communication Type” is selected the setting ”Modbus Serial”, the following properties will appear:   * **Communication Type** Define the method and mean of communication. Serial over TCP is used when a Serial Server is used.\\ If in the property ”Communication Type” is selected the setting ”Modbus Serial”, the following properties will appear:
-    * Port Number: Serial port number. It can be between 0 and 3. For USB use 10.+    * Port Number: Serial port number that changes depending on the server used: 
 +      * Compact: use 0. 
 +      * Rack: for the 2 RS-232 ports use and 1. For the additional green ports use 2 and 3
 +      * Brickbox: for RS-232 use 4. For RS-485 use 5. 
 +      * When using a USB port, use 10.
     * Baud Rate: Modbus Baud Rate     * Baud Rate: Modbus Baud Rate
     * Data Length: Number of bits for data     * Data Length: Number of bits for data
Line 1215: Line 1219:
  
   * **IP Address** IP address of the device or of the serial server   * **IP Address** IP address of the device or of the serial server
-  * **Port Number** Serial port number. It can be between 0 and 3. For USB use 10+  * **Port Number** Serial port number that changes depending on the server used: 
 +      * Compact: use 0. 
 +      * Rack: for the 2 RS-232 ports use and 1. For the additional green ports use 2 and 3
 +      * Brickbox: for RS-232 use 4. For RS-485 use 5. 
 +      * When using a USB port, use 10.
   * **Lights** Collection of lights   * **Lights** Collection of lights
   * **Automation**    * **Automation** 
Line 1322: Line 1330:
 {{ :system_obj_-_zwave.png?nolink&100 |}} {{ :system_obj_-_zwave.png?nolink&100 |}}
  
-It allows to integrate Z-Wave devices. Without any gateway, the result is a reliable and easy-to-use system with a bidirectional connection between Z-Wave and other standards such as KNX.+It allows to integrate Z-Wave devices. Without any gateway, the result is a reliable and easy-to-use system with a bidirectional connection between Z-Wave and other standards such as KNX.  
 + 
 +<WRAP important center round 60%> For a full list of all the compatible Z-wave devices with Thinknx server, visit this link here http://www.thinknx.com/v3/php/products.php. </WRAP>
  
   * **Use internal controller** If enable, it will be used the server internal Z-Wave controller. If disabled it will be possible to use an external Z-Wave controller. This option is only used during configuration phase. If disabled, following properties will appear:   * **Use internal controller** If enable, it will be used the server internal Z-Wave controller. If disabled it will be possible to use an external Z-Wave controller. This option is only used during configuration phase. If disabled, following properties will appear:
Line 1594: Line 1604:
 This object represents the interface between ThinKnx system and a third-party device connected through serial port. It makes possible to send commands through the serial port to the device. This object represents the interface between ThinKnx system and a third-party device connected through serial port. It makes possible to send commands through the serial port to the device.
  
-  * **Port Number** Serial port number. It can be between 0 and 3. For USB use 10.+  * **Port Number** Serial port number that changes depending on the server used: 
 +      * Compact: use 0. 
 +      * Rack: for the 2 RS-232 ports use and 1. For the additional green ports use 2 and 3
 +      * Brickbox: for RS-232 use 4. For RS-485 use 5. 
 +      * When using a USB port, use 10.
   * **Baud Rate** Serial port baud rate.   * **Baud Rate** Serial port baud rate.
   * **Data Length** Number of bits for data.   * **Data Length** Number of bits for data.
Line 1855: Line 1869:
      * IP address: Device IP address.      * IP address: Device IP address.
      * Port number: TCP/IP port number for ethernet connection.\\ If the property ”Use serial port” is set to ”Enabled”, the following property will be displayed:      * Port number: TCP/IP port number for ethernet connection.\\ If the property ”Use serial port” is set to ”Enabled”, the following property will be displayed:
-     * Serial port: Server serial port number.+     * Serial port: Serial port number that changes depending on the server used: 
 +      * Compact: use 0. 
 +      * Rack: for the 2 RS-232 ports use 0 and 1. For the additional green ports use 2 and 3. 
 +      * Brickbox: for RS-232 use 4. For RS-485 use 5. 
 +      * When using a USB port, use 10.
  
 ==== Object commands ==== ==== Object commands ====
Line 1892: Line 1910:
     * IP address: Device IP address.     * IP address: Device IP address.
     * Port number: TCP/IP port number for ethernet connection.\\ If the property ”Use serial port” is set to ”Enabled”, the following property will be displayed:     * Port number: TCP/IP port number for ethernet connection.\\ If the property ”Use serial port” is set to ”Enabled”, the following property will be displayed:
-    * Serial port: Server serial port number.+    * Serial port: Serial port number that changes depending on the server used: 
 +      * Compact: use 0. 
 +      * Rack: for the 2 RS-232 ports use 0 and 1. For the additional green ports use 2 and 3. 
 +      * Brickbox: for RS-232 use 4. For RS-485 use 5. 
 +      * When using a USB port, use 10.
   * **Mute KNX Group** KNX group for mute command.   * **Mute KNX Group** KNX group for mute command.
  
Line 1935: Line 1957:
     * //TV brand LCD//     * //TV brand LCD//
     * //TV brand NEC//     * //TV brand NEC//
-  * **Serial port** Server serial port number.+  * **Serial port** Serial port number that changes depending on the server used: 
 +      * Compact: use 0. 
 +      * Rack: for the 2 RS-232 ports use 0 and 1. For the additional green ports use 2 and 3. 
 +      * Brickbox: for RS-232 use 4. For RS-485 use 5. 
 +      * When using a USB port, use 10.
  
 ==== Object Commands ==== ==== Object Commands ====
Line 1977: Line 2003:
     * IP address: Device IP address.     * IP address: Device IP address.
     * Port number: TCP/IP port number for ethernet connection.\\ If the property ”Use serial port” is set to ”Enabled”, the following property will be displayed:     * Port number: TCP/IP port number for ethernet connection.\\ If the property ”Use serial port” is set to ”Enabled”, the following property will be displayed:
-    * Serial port: Server serial port number. +    * Serial port: Serial port number that changes depending on the server used: 
 +      * Compact: use 0
 +      * Rack: for the 2 RS-232 ports use 0 and 1. For the additional green ports use 2 and 3. 
 +      * Brickbox: for RS-232 use 4. For RS-485 use 5. 
 +      * When using a USB port, use 10.
  
 ==== Object commands ==== ==== Object commands ====