Thinknx Server Web Interface
The Thinknx server web interface allows you to manage, configure, and monitor the device through a standard web browser, without using additional software.
Through this interface, it is possible to view server information, modify network settings, manage licenses, configure cloud services, perform updates, and use diagnostic tools.
The available functions may vary depending on the server model, installed firmware version, and active licenses.
Warning
Changing the settings available through the web interface may affect the operation of the server and the entire installation.
It is recommended to make changes only when the function of the relevant parameters is fully understood and to create a backup of the settings beforehand.
1. Accessing the Web Interface
To access the web interface, you need to know the IP address of the Thinknx server.
Connect the computer to the same local network as the server and open a web browser.
Enter the IP address of the device in the browser address bar.
Starting from firmware 1.1.10.25, the new web interface is available through HTTPS on port 443.
The previous web interface is also available through HTTP on port 5051.
| Interface | Protocol | Port | Example |
|---|---|---|---|
| New web interface | HTTPS | 443 | https://192.168.1.200 |
| Previous web interface | HTTP | 5051 | http://192.168.1.200:5051 |
The IP addresses shown are examples only and must be replaced with the actual IP address of the server.
Authentication
To access the settings, you must log in using the server credentials.
Once authenticated, the following information is displayed at the top of the page:
- Name of the connected user.
- Date and time of the last login.
- Button to change the password.
- Button to log out.
For security reasons, it is recommended to change the default credentials and not share them with unauthorized users.
2. Interface Structure
The web interface is organized through a main menu located at the top of the page.
The main available sections are:
| Section | Description |
|---|---|
| Home | Main page with quick links, information, and maintenance operations. |
| Config | Configuration export and management of server settings cleanup operations. |
| Server | Configuration and administration of device functions. |
| Reboot | Reboot and shutdown operations. |
| Monitor | Access to the server Log Monitor and KNX Bus Monitor. |
| Logout | Logs the user out of the web interface. |
3. Home
The Home page provides an overview of the device and allows quick access to the main functions.
It is divided into several areas.
Quick Links
The Links section provides direct access to the following functions:
- Upload configuration: opens the page dedicated to project upload and settings management.
- Network & KNX: allows you to configure the network parameters and the connection to the KNX bus.
- Language: allows you to change the language of the web interface.
- Bus Monitor: opens the KNX traffic monitoring tool.
Maintenance
The Maintenance section allows you to perform reboot and shutdown operations.
Three commands are available:
| Command | Function |
|---|---|
| Quick Reboot | Restarts the server software. |
| Full Reboot | Completely restarts the device. |
| Shutdown | Shuts down the server. |
During reboot or shutdown operations, the server may temporarily become unavailable.
Before proceeding, make sure that no configuration, project transfer, or maintenance operations are currently in progress.
Server Information
A summary of the main device information is displayed at the bottom of the Home page.
This includes:
- License owner.
- Serial number.
- Server ID.
- MAC address.
- Firmware version.
- Maximum number of clients.
This information may be requested by Thinknx Technical Support to identify the device and verify compatibility with the available functions.
4. Configuration Management
The Config section allows you to upload a new configuration, export the server settings, and perform cleanup and reset operations.
The main available operations are:
- Uploading a new configuration generated using Thinknx Configurator.
- Downloading a backup of the settings.
- Deleting Configurator settings.
- Deleting user settings.
- Restoring factory settings.
Uploading the Configuration
This function allows you to upload a new configuration to the server, generated through a dedicated export from the Thinknx Configurator software.
To proceed:
- Open the project in Thinknx Configurator.
- Use the dedicated export command to upload the configuration to the server.
- Save the generated file on the computer.
- Open the Config section of the web interface.
- Click Select file and select the previously exported file.
- Click Upload to start the transfer.
- Wait for the procedure to complete and check the confirmation message.
The configuration can also be uploaded through the deployment functions of Thinknx Configurator.
Saving the Settings
The Download button allows you to download a backup of the settings stored on the server.
The file contains information related to the device configuration, such as scenarios, automations, and other settings.
The backup can also be sent to Thinknx Technical Support to allow the settings to be analyzed and to retrieve information that may be useful for troubleshooting.
It is recommended to create a backup before changing server settings, performing updates, or carrying out extraordinary maintenance operations.
When requesting technical assistance, Technical Support may ask for this file to perform additional checks.
Deleting Configurator Settings
The Delete Configurator settings command deletes the scenario settings derived from the uploaded project.
This operation causes the server to reboot.
Deleting User Settings
The Delete user settings command deletes settings customized by the user, such as schedules, scenarios, and initial data.
This operation causes the server to reboot.
Factory Reset
The Factory reset button deletes all settings and the project stored on the device, returning the server to its factory state.
The operation causes a full reboot of the server.
Warning: data loss
Delete and reset operations may cause irreversible loss of stored information.
Before proceeding, make sure that the original project and an up-to-date backup of the settings are available.
5. Server Menu
The Server menu contains the main configuration and administration settings of the device.
The available sections include:
- Status.
- Access Control.
- License & Code.
- Users.
- Network & KNX.
- Updates.
- Date & Time.
- Voice Control.
- ThinknxCloud.
- Integration Kit.
- Memory Status.
- Language.
The following sections describe the main available functions.
5.1 Server Status
The Status section allows you to view information related to the device and its operation.
The displayed information includes:
Device Identification
- License owner.
- Serial number.
- Server ID.
- MAC address.
- Software version.
Connections and Operation
- Maximum number of supported clients.
- Current number of connected clients.
- Code of the last connected client.
- IP address of the last connected client.
- Time elapsed since server startup.
- Time elapsed since process startup.
- Date and time of the uploaded configuration.
Hardware Information
When available, the following information is also displayed:
- Number of registered PBXs.
- VNC connection status.
- Temperature.
- Humidity.
- Brightness.
The Calibrate sensor button allows you to access calibration of the available sensors.
Enabled Licenses
The list of functions enabled on the device is displayed at the bottom of the page.
The available licenses depend on the commercial configuration of the server.
5.2 Access Control
The Access Control section allows you to manage the codes used by the access control functions.
It is possible to:
- View existing codes.
- Create new codes.
- Modify or delete codes.
- Assign a role.
- Configure a validity interval.
- Apply a time schedule.
- Assign additional areas.
- Export codes.
The code table allows you to view the status and properties of each entry.
Before deleting or modifying a code, make sure that it is not being used by any access control device or function in the installation.
5.3 License & Code
The License & Code section allows you to manage license codes and clients authorized to connect to the server.
License Codes
License codes enable the functions available on the Thinknx server.
The page allows you to view installed codes and add new licenses.
To add a license:
- Request the license code from Thinknx by providing the server identification information.
- Enter the code in the dedicated field.
- Click Add license.
Client Codes
Each client authorized to connect is identified by a code.
The section allows you to:
- View registered clients.
- Enable or disable codes.
- Modify the description.
- Manage the available properties.
- Delete codes that are no longer required.
- Add new client codes.
The page also displays the maximum number of enabled clients and information about the last connected client.
Push Notification
The Push Notification section allows you to send a push notification to enabled users.
This function can be used to communicate information to users through the client devices associated with the server.
5.4 User Management
5.5 Network & KNX
The Network & KNX section allows you to configure server connectivity and settings related to the KNX bus.
The page is divided into several areas.
Ethernet Configuration
The first section displays the network settings currently in use.
These include:
- DHCP client status.
- IP address.
- Subnet Mask.
- Gateway address.
- Primary DNS.
- Secondary DNS.
It is possible to enable DHCP or manually configure the network parameters.
For manual configuration, enter the required values and click Save network changes.
After changing the server IP address, it may be necessary to reopen the browser using the new address.
Before saving, make sure that the parameters are compatible with the installation network.
Wi-Fi Configuration
Wi-Fi configuration is available exclusively on Envision_20 servers.
The page allows you to enable or disable the device Wi-Fi interface.
After changing the setting, click Save Wi-Fi network changes.
The first activation may require a full reboot of the device.
Network Diagnostics
The Network Diagnostics section allows you to check the connection status and the reachability of the services required for server operation.
Scroll down to the Network Diagnostics section and click the Check status button.
The page dedicated to checking network connections and services will open.
Click Check network to start the checks.
The diagnostics check the following services:
- Ethernet connection: checks external network resolution, an essential prerequisite for cloud services.
- Thinknx Cloud: checks connectivity to Thinknx Cloud services.
- Remote client connection: checks whether the server can be reached from the Internet through the client port.
- Remote assistance: checks the availability of the service used by Thinknx Technical Support.
- Remote maintenance: checks the connectivity required by the Remote Maintenance service.
- External DNS resolution: checks that the MyThinknx ID points to the server's current public IP address.
Understanding the Results
At the end of the check, each service is identified by a colored indicator representing its status.
- Green – OK: the service is reachable and working correctly.
- Yellow – Warning: some connectivity issues have been detected. The diagnostics indicate the ports or services that cannot be reached. These issues do not necessarily affect all server functions.
- Red – Error: the required connectivity is unavailable and the affected functions cannot be used.
If a yellow or red indicator is displayed, check the diagnostic details to identify the ports or services that cannot be reached.
Not all checked services are required for normal server operation: their availability depends on the functions used in the installation.
For more information about checking the connectivity required for Remote Maintenance, see:
KNX Settings
This section allows you to configure how the KNX settings are used.
The following options are available:
- Overridden: uses the settings defined directly in the web interface.
- From project: uses the settings provided by the Thinknx Configurator project.
The available settings include the KNX physical address and activation of the KNXnet/IP interface.
After making the required changes, click Save KNX settings changes.
For a complete explanation of KNXnet/IP interface configuration, see:
VNC Server
The VNC section allows you to enable or disable the device VNC service.
The service allows remote access to the server graphical interface through a VNC client.
The port used is:
5900 TCP
To change the service status:
- Select Start VNC or Stop VNC.
- Click Save VNC changes.
It is recommended to use VNC only on trusted networks or through protected remote connections, avoiding direct exposure of the service to the Internet.
5.6 Updates
The Updates section allows you to check whether new software versions are available for the Thinknx server.
To check for available updates:
- Open the Updates section.
- Make sure that the server has a working Internet connection.
- Click Check updates.
- Wait for the search to complete.
If compatible updates are available, it will be possible to proceed by following the instructions displayed.
Before updating the server, make sure that a backup of the project and settings is available.
Do not disconnect the device from the power supply during the update.
The availability of updates and functions may depend on the hardware revision of the server.
5.7 Date & Time
The Date & Time section allows you to configure the server internal clock.
The page displays:
- Current time zone.
- Current time.
- Current date.
- Internet synchronization status.
- Configured NTP server.
Internet Synchronization
Automatic synchronization through an NTP server can be enabled.
To configure it:
- Enable Internet synchronization.
- Select the time zone.
- Enter the NTP server address.
- Save the changes.
Manual Configuration
When automatic synchronization is not used, the following values can be entered manually:
- Hour.
- Minutes.
- Day.
- Month.
- Year.
Click Save changes to apply the new values.
Correct date and time configuration is important for the operation of schedules, automations, logs, and services that use time-related information.
5.8 Voice Control
The Voice Control section allows you to manage Thinknx server integrations with voice assistants.
The integrations include:
- Apple HomeKit: displays the pairing code and allows pairing and service reset operations to be managed.
- Amazon Alexa: displays the pairing status and allows management of the connected account.
- Google Home: Soon to be available.
For more information about configuring and using voice integrations, see the dedicated guide:
5.9 ThinknxCloud
The ThinknxCloud section allows you to manage the server parameters associated with Thinknx cloud services.
The page is divided into three main areas:
- Cloud service configuration and status.
- Thinknx Portal user management.
- Remote Maintenance.
Initial ThinknxCloud Activation
To use ThinknxCloud services, an initial configuration must be performed directly from the server web interface.
Open:
Server → ThinknxCloud
Click the Enable ThinknxCloud button.
During the procedure, you will be asked to enter:
- Installer email address: email address to be associated with the ThinknxCloud service.
- Cloud password: password dedicated to the server, used to upload and manage projects through the Cloud.
Once the configuration is complete, the Cloud service will be enabled and the related management settings will become available.
The Cloud password is specific to the server and is used to authorize project uploads through ThinknxCloud.
It must not be confused with the password used to access the server web interface or with the Thinknx Portal account password.
ThinknxCloud Configuration
Once the service has been enabled, the page displays the current settings.
The available information includes:
- Cloud activation status.
- Cloud connection status.
- Associated email address.
- MyThinknx activation status.
- MyThinknx ID.
- Subscription code.
- Subscription expiration date.
- Available services.
- Integration Kit status.
- Used and available storage space.
Several commands are available for managing the service:
| Command | Description |
|---|---|
| Disable ThinknxCloud | Disables the Cloud service. |
| Change email address | Changes the associated email address. |
| Change subscription code | Allows the subscription code to be changed. |
| Change Cloud password | Changes the Cloud service password. |
| Change MyThinknx settings | Allows the MyThinknx settings to be changed. |
| Disable Integration Kit | Disables the Integration Kit service. |
| Delete all data from Cloud | Starts the procedure for deleting data stored in the Cloud. |
Before disabling Cloud services or deleting stored data, check the consequences for the installation functions that depend on these services.
Thinknx Portal Users
This section allows you to associate new Thinknx Portal users with the server and view accounts that are already connected.
To associate a new user:
- Click Associate a user.
- Log in to the Thinknx Portal.
- Complete the association procedure.
Once associated, the user is displayed in the dedicated table.
The page also allows you to view user information and remove existing associations.
Remote Maintenance
The Remote Maintenance function allows the System Integrator to establish a tunnel to the server through the Internet.
The tunnel allows access to the device web interface and allows ETS to be used to perform KNX programming operations remotely.
The page allows you to enable or disable the service and view the current connection status.
Remote Maintenance requires a System Integrator account on the Thinknx Portal and a server associated with the same account.
For details about prerequisites, activation, and ETS configuration, see the dedicated guide:
5.10 Integration Kit
The Integration Kit section allows you to manage the service dedicated to integration with external applications and systems.
Through this function, it is possible to use the integration interfaces provided by the Thinknx server.
For API configuration and usage, refer to the dedicated Integration Kit documentation.
5.11 Memory Status
The Memory Status section allows you to check the health status of the Thinknx server internal memory.
By clicking Start memory check, the server performs a memory verification procedure.
This function is useful for identifying possible problems related to the internal memory of the device.
The procedure may require a server reboot.
Before performing the check, a backup of the settings must be created, since in case of severely damaged memory, problems may occur during the error correction process.
5.12 Language
The Language section allows you to change the language used by the web interface.
The available languages are:
- English.
- Italiano.
- Deutsch.
Select the required language to change how the pages are displayed.
6. Reboot and Shutdown
The Reboot menu provides access to device maintenance operations.
The same commands are available on the Home page.
Quick Reboot
Restarts the server software without performing a full reboot of the device.
Full Reboot
Completely restarts the Thinknx server.
During this operation, the device will temporarily be unreachable.
Shutdown
Starts the server shutdown procedure.
Before performing a full reboot or shutdown, make sure that no update, project upload, or other maintenance activity is currently in progress.
7. KNX Bus Monitor
The Monitor menu provides access to the server monitoring tools.
By selecting KNX Bus Monitor, it is possible to view traffic on the KNX bus and interact directly with group addresses.
The monitor is divided into several areas.
Bus Traffic
The main table displays the detected KNX telegrams.
The displayed information includes:
- Time: time when the telegram was received.
- Sender: physical address of the sending device.
- Destination: destination group address.
- Data: value carried by the telegram.
The monitor periodically updates the displayed telegrams.
A command is also available to clear the messages currently displayed.
Sending Telegrams
The sending section allows you to write or read values on the KNX bus.
The following parameters can be configured:
- Group address.
- Data length.
- Data type.
- Available options.
- Value to send.
The Send and Read buttons respectively allow you to send a telegram or perform a read request.
Sending KNX telegrams can directly modify the status of devices in the installation.
Use this function only when the correct group address and data type are known.
KNX Recorder
The KNX Recorder function allows KNX telegram recording to be enabled.
The page displays:
- Recorder status.
- Database size.
- Available space.
Log Export
Recorded telegrams can be exported in an XML format compatible with ETS.
The available filters allow you to select:
- Time period.
- Destination group address.
- Physical address of the sending device.
After configuring the parameters, click Download log for ETS.
8. Log Monitor
The Log Monitor section, accessible from the Monitor menu, allows you to view logs generated during operation of the Thinknx server.
Through this page, it is possible to view system messages and information related to operations performed by the server.
Logs are a useful tool for checking device behavior and identifying possible anomalies during operation of the installation.
The displayed information may include:
- System messages.
- Information related to service operation.
- Errors or anomalies.
- Diagnostic messages generated during operations.
Technical Support
In case of problems, the information available in the Log Monitor may be useful to Thinknx Technical Support for analyzing server behavior and identifying possible causes of the reported anomalies.
9. Troubleshooting
Unable to Access the Web Interface
- Make sure that the server is switched on and correctly powered.
- Make sure that the computer is connected to the correct network.
- Check the IP address being used.
- Check device reachability using ping.
- Make sure that the correct protocol and port are being used.
- Check for any network or firewall restrictions.
Unable to Access the Server After Changing the Network Settings
- Check the newly configured IP address.
- Make sure that the address belongs to the correct network.
- Check the subnet mask and gateway.
- Reopen the browser using the new address.
The Server Cannot Reach Cloud Services
- Check the Internet connection.
- Check the gateway and DNS configuration.
- Run the diagnostics in the Network & KNX section.
- Check the connection status on the ThinknxCloud page.
KNX Functions Are Not Available
- Check the physical connection to the KNX bus.
- Check the KNX settings in the Network & KNX section.
- Make sure that the KNXnet/IP interface is enabled, if required.
- Check the KNX Bus Monitor to verify bus traffic.
Problems During an Update
- Make sure that the Internet connection is stable.
- Check the current firmware version.
- Check the hardware compatibility of the device.
- Do not disconnect the power supply during the update.
Checking System Logs
If anomalies occur during server operation, open:
Monitor → Log Monitor
Check for any error messages or diagnostic information that may help identify the problem.
If the problem persists, contact Thinknx Technical Support and provide the server model, serial number, firmware version, and a description of the reported anomalies.
10. Related Guides
For additional information about individual functions, see the dedicated guides: